1
/
von
1
Eaton HMCP150T4S Series C Motor Circuit Protector (F‑Frame), 3‑Pole, 150 A, Magnetic‑Only Trip, 600 VAC / 250 VDC — Line & Load Stainless Steel Terminals
Eaton HMCP150T4S Series C Motor Circuit Protector (F‑Frame), 3‑Pole, 150 A, Magnetic‑Only Trip, 600 VAC / 250 VDC — Line & Load Stainless Steel Terminals
Normaler Preis
$1,360.00 USD
Normaler Preis
Verkaufspreis
$1,360.00 USD
Versand wird beim Checkout berechnet
Anzahl
Verfügbarkeit für Abholungen konnte nicht geladen werden
Secure checkout via Stripe & PayPal
Product: Eaton HMCP150T4S — Series C Motor Circuit Protector (HMCP), F‑Frame
Overview
- Manufacturer: Eaton
- Model: HMCP150T4S (Series C, HMCP family)
- Product type: Motor Circuit Protector (MCP), motor protection device for NEMA size 4 starter applications
- Quantity: single unit
Key electrical specifications
- Amperage rating: 150 A (device rating)
- Trip type: Magnetic‑only (instantaneous magnetic trip for short‑circuit/locked‑rotor protection; no thermal overload element)
- Magnetic trip rating (adjustable range): 450–1500 A
- Voltage rating: 600 VAC; 250 VDC
- Number of poles: Three‑pole
Mechanical & connection specifications
- Frame: F (F‑frame physical size)
- Terminals: Line and load rated stainless steel terminals
- Terminal material: Stainless steel
- Mounting / application: Designed for use in motor starter assemblies (NEMA size 4 starters); compatible with Series C enclosure and starter configurations
Dimensions & weight
- Depth (Length): 7.6 in
- Height: 4.25 in
- Width: 4.9 in
- Weight: 4.25 lb
Safety & certifications
- UL Listed (refer to Eaton datasheet and markings for exact UL file/reference)
Features & typical applications
- Magnetic‑only trip provides reliable short‑circuit and locked‑rotor protection for motors where separate overload protection is provided by other means (e.g., thermal relays or electronic motor protection).
- Ideal for industrial motor control, NEMA size 4 starter installations, and applications requiring a robust, compact MCP with stainless steel terminations.
- Line and load rated terminals simplify wiring and replacement.
Ordering & installation notes
- Confirm coordination with upstream protection and downstream motor overload devices; magnetic trip range 450–1500 A must be set/selected in accordance with motor locked‑rotor current and system coordination practices.
- Observe manufacturer installation instructions and torque specifications. Use only Eaton‑specified accessories and mounting hardware for compliance and safety.
- For full electrical curves, adjustment instructions, recommended accessories, and installation details consult the Eaton HMCP product datasheet and installation manual.
Datasheet & support
- Refer to Eaton official datasheet for HMCP series and the HMCP150T4S catalog entry for complete technical data, performance curves, and UL references.